SCPD 56/26 DIN By-Pass
With two separate flows and a directly mounted By-Pass valve, the Sunfab’s SCPD 56/26 By-Pass DIN is the most flexible compact fixed flow pump on the market.
SCPD 56/26 DIN By-Pass is ideal for combination vehicles which require different flows and where there is a need to operate equipment while moving. The pump is primarily intended for engine-mounted power take-offs. The constant engagement is made possible by the By-Pass valve, which immediately relieves the load on the pump and power take-off when oil is not required. The pressure drop of the By-Pass valve is very low, so its function is energy efficient.
                        Product Benefits
The By-Pass valve can relieve the load from full operating pressure of 400 bar, which allows emergency stop function
The valve´s 24 V solenoids have integrated electrical cables which meet protection class ADR
Technical specifications
| SCPD 56/26 DIN By-Pass | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Theoretical oil flow, A+B at pump speed | |||||||||||
rpm  | 
600 1000 1200 1500 1800  | 
l/min 34+16=50 56+26=82 67+31=98 84+39=123 101+47=148  | 
|||||||||
| Displacement A+B | |||||||||||
| cm3/rev | 56.0+26.1 | ||||||||||
| Max pump speed A+B | |||||||||||
| rpm | 1850 | ||||||||||
| Max pump speed A | |||||||||||
| rpm | 1850 | ||||||||||
| Max pump speed B | |||||||||||
| rpm | 2200 | ||||||||||
| Max pump speed, relieved | |||||||||||
| rpm | 2700 | ||||||||||
| Max working pressure | |||||||||||
| bar | 400 | ||||||||||
| Weight without valve | |||||||||||
| kg | 18.0 | ||||||||||
| Weight with valve | |||||||||||
| kg | 22.5 | ||||||||||
| Tare-weight torque without valve | |||||||||||
| Nm | 21.0 | ||||||||||
| Tare-weight torque with valve | |||||||||||
| Nm | 25.5 | ||||||||||
| Theoretical power at pressure and pump speed | |||||||||||
rpm  | 
600 1200 1800  | 
200 
 Bar 
11.2+5.2=16.4 kW 22.4+10.4=32.8 kW 33.6+15.6=49.2 kW  | 
300
 Bar 
16.8+7.8=24.6 kW 33.6+15.6=49.2 kW 50.4+23.4=73.8 kW  | 
400
 Bar 
22.4+10.4=32.8 kW 44.8+20.8=65.6 kW 67.2+31.2=98.4 kW  | 
|||||||
| Nominal torque on pump shaft at different pressures | |||||||||||
| 200 
 Bar 
178+83=261 Nm 
 | 
300 
 Bar 
267+124=391 Nm 
 | 
400 
 Bar 
356+165=521 Nm 
 | 
|||||||||
| Direction of rotation | |||||||||||
| Left (L) or Right (R) | |||||||||||